The latest model of REGAMOUNT™ head-mounted temperature transmitter in an explosion-proof enclosure. Universal input supports RTD (PT50/100/500/1000), Thermocouples (T/E/J/K/N/R/S/B), mV, and Ω sensors. True full galvanic isolation up to 1000VDC.
| Sensor Type | Model | Range | Min. Range | Accuracy |
|---|---|---|---|---|
| Thermocouple | T | -200~400°C | 25°C | ±0.4°C |
| Thermocouple | E | -200~1000°C | 25°C | ±0.4°C |
| Thermocouple | J | -210~1200°C | 25°C | ±0.4°C |
| Thermocouple | K | -200~1372°C | 25°C | ±0.4°C |
| Thermocouple | N | -200~1300°C | 25°C | ±0.4°C |
| Thermocouple | R | 0~1768°C | 100°C | ±0.8°C |
| Thermocouple | S | 0~1768°C | 100°C | ±0.8°C |
| Thermocouple | B | 150~1820°C | 100°C | ±1.0°C |
| RTD | PT50 | -200~850°C | 10°C | ±0.15°C |
| RTD | PT100 | -200~850°C | 10°C | ±0.15°C |
| RTD | PT500 | -200~850°C | 10°C | ±0.1°C |
| RTD | PT1000 | -200~850°C | 10°C | ±0.1°C |
| mV Input | — | -120~120mV | 10mV | ±10µV |
| mV Input | — | -1000~1000mV | 50mV | ±100µV |
| Ω Input | — | 0~500Ω | 100Ω | ±0.2Ω |
| Ω Input | — | 0~4500Ω | 100Ω | ±1.0Ω |
HART output • Universal input without sensor • No LCD • IP65 safe area • SS304 bracket
⚠ Notice:
When sensor order code is "0" (without integrated sensor), the user must prepare suitable sealing for assembling the remote sensor in its conduit to achieve the desired IP rating and explosion-proof protection.
Contact our technical team for sensor selection, custom configurations, and competitive pricing.
Request Quote →